Large view
Small footprint
TECH
CONTRIBUTES
HEALTH
Upgraded FPD
Revealing more anatomical details
- lncreasing 100% of Field of View
Equipped with 30cm*30cm large size dynamic FPD, imaging area has been increased by 100%compared with the conventional FPD.
- Crystal-clear image with delicacy
4MP resolution image combined with low signal-noise ratio reveals tiniest anatomicaldetails.
Double the image size
Decrease exposure times
- Full lumbar vertebrae imaging
5 lumbar vertebrae can be photographed within one image by a 30cm x 30cm FPD, largely decreasing exposure times caused by insufficient image FOV, making it easier for surgeon to locate lesions and to make surgical plan in the procedure like pedicle screw fixation or procedure with strict imaging demand.
- Entire pelvic imaging
lmage taken by 30cm x 30cm FPD can basicly cover the entire pelvic floor. In the surgery of bilateral-pevicfractures or pelvic ring internal fixation, all the fracture site can be revealed by a single exposure, which significantly improves overall efficiency.
Clinical image
Clinical application
- Joint surgery
lmage with high resolution can clearly reveal articular structure, helping surgeons to better locate the target
- Trauma surgery
Flexible mechanical movement realize easy positioning for different type of trauma surgery, providing comfortable handling experience.
- Spine surgery
upgraded FPD present more details of vertebrae, helping surgeons to better making surgical plans.
- Pain management
Multiple radiation protection decrease overall exposure times during minimally invasive procedure.
Low dose management
Multiple protection
- Lower leakage radiation in the loading state
Leakage radiation in the loading state of X-ray tube is far more lower than CFDA and FDA standard, providing better protection from the X-ray source.
- High frequency pulsed fluoroscopy
X-ray generated in high frequency pulse wave can decrease 50% of radiation dose compared with a continous fluoroscopy. This particular technology has a positive effect on weaking the motion artifact.
- Dose area product monitoring
Real time DAP meter displayed on image.Easy for monitoring radiation level.
- Intelligent parameter adjustment
Optimized and adjustable exposure parameter created by intelligent hardware and algorithm provide a friendly examination scenario.
- Virtual collimator
Allowing radiologist to preview and to adjust exposure area before exposure, reducing unnecessary radiation.
- Aluminum beam filtration
Decreasing radiation level by absorbing soft X-ray.Ensuring high quality image for precise diagnosis and treatment.
没有评论:
发表评论